      包米勒驅(qū)動(dòng)器報(bào)2740錯(cuò)誤代碼維修

      發(fā)布時(shí)間:2023/9/26點(diǎn)擊次數(shù):950

       

      2740No polynomial curve data available
      沒有可用的多項(xiàng)式曲線數(shù)據(jù).
      It was tried to release the drive in the operation mode "Coupled
      mode" but there is no polynomial curve data in the controller.
      嘗試在“耦合"操作模式下釋放驅(qū)動(dòng)器模式",但控制器中沒有多項(xiàng)式曲線數(shù)據(jù)。


      m Consequence:
      The operation in the coupled mode isn't possible. Behavior accordant to set error reaction.
      在耦合模式下操作是不可能的。根據(jù)設(shè)置錯(cuò)誤反應(yīng)的行為。


      2006Overvoltage in mains電源中的過電壓。
      The active mains rectifier unit has measured a voltage of over 530 V
      effective in the mains.
      有源電源整流器單元測(cè)量到的電壓超過530 V在電源中有效。


      Possible causes: 可能的原因:
      The mains voltage has risen to over 530 V or the measurement
      switch for the mains voltage measurement is defective.
      電源電壓已升至530 V以上或測(cè)量值電源電壓測(cè)量開關(guān)有故障。

       